  • The ROTINA 420 R can handle large volumes. Its maximum capacity of 4 x 600 ml, 140 blood collection tubes or 16 microtitre plates makes it exceptionally suitable for use in medical diagnostics (clinical chemistry). It is also a reliable tool for long term use in biotechnology and pharmaceutical research laboratories. The temperature of the centrifuge can be set to any value in the range -20 °C to +40 °C. The temperature can also be set in Fahrenheit. If toxic or infectious material is centrifuged, then the TÜV-tested accessories with bioseals can protect against aerosols. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 4780 carrier can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020 PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 600 ml in an angle rotor: 4 x 250 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 423 x 713x 654 mm Weight: approx. 108 kg Refrigeration: infinitely variable from – 20°C to +40°C Frequently used rotors: Swing-out rotor for 4 x 600 ml (90°), max. RCF 4,740 – Cat. No. 4784-A Angle rotor for 30 x 1.5 / 2 ml, max. RCF 24,400 – Cat. No. 4790-A Angle rotor for 4 x 250 ml, max. RCF 12,007 – Cat. No. 4795 Angle rotor for 6 x 94 ml, max. RCF 16,504 – Cat. No. 4794 OPERATOR COMFORT The ROTINA 420 R makes everyday centrifugation easier thanks to its ergonomic design. The centrifuge has the following features: Motor-driven lid locking Ergonomic operating and information panel Simple rotor change Ergonomic C control panel 98 programmable memories Additional storage capacity is reserved for the pre-cooling program PREC SAFETY The ROTINA 420 R allows complex tasks to be accomplished easily. It provides the highest degree of safety through the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection Chamber overheating protection DESIGN The ROTINA 420 R is a compact benchtop centrifuge that can handle large volumes. It features components such as: Metal casing Centrifugation chamber of rust-free stainless steel View port in the lid Advantages High-speed and adaptable laboratory centrifuge for daily use in research or analytical laboratories This high-performance centrifuge can hold 4 x 600 ml samples, 140 blood collection tubes or 16 microtitre plates The temperature of the centrifuge can be set to any value in the range -20 °C to +40 °C, with pre-cool program and stand-by cooling The TÜV-tested accessories with bioseals contribute to safe working procedures Compact benchtop centrifuge Ergonomic C control panel allows complex centrifugation programs to be entered, stored and called up as required 98 programmable memories 9 braking and run-up ramps, run-down without braking and braking switch-off speed can be selected as required Fields of application The ROTINA 420 R is a reliable tool for use in laboratories in Medical diagnostics (clinical chemistry) Biotechnology research Pharmaceutical research
  • Max. capacity: in a drum rotor: 60 x 1,5 / 2 m in an angle rotor: 48 x 1,5 / 2 ml in a swing-out rotor: 24 x 1,5 / 2 ml Max. speed (RPM): 18.000 Max. RCF: 31.514 Dimensions (H x W x D): 313 x 330 x 420 mm Weight: approx. 21 kg Refrigeration: Air cooling Frequently used rotors: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 31,514 – Cat. No. 1195-A Angle rotor for 48 x 1.5 / 2 ml, two-row, max. RCF 21,255 (outer row) 18,845 (inner row) – Cat. No. 1158-L Swing-out rotor for 24 x 1.5 / 2 ml (90°), max. RCF 18,516 – Cat. No. 1154-L
  • Max. capacity in an angle rotor: 30 x 1.5 / 2 ml Max. speed (RPM): 15,000 Max. RCF: 21,382 Dimensions (H x W x D): 260 x 281 x 553 mm Weight: approx. 28 kg Refrigeration: Infinitely variable from -20 °C to +40 °C Frequently used rotors: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 21,382 – Cat. No. 2424-B Angle rotor for 30 x 1.5 / 2 ml, two-row, max. RCF 20,627 – Cat. No. 2427-A Angle rotor for 30 x 0.5 ml, max. RCF 20,376 – Cat. No. 2430-B
  • The ROTO SILENTA 630 RS centrifuges blood bags safely and efficiently. This centrifuge can reliably handle large volumes: Its maximum capacity is 6 x 2,000 ml / 12 x 750 ml blood bags.
  • An RCF of 6,446 can be achieved in a swing-out rotor and a value of 24,400 in an angle rotor. The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F). The centrifuge additionally has stand-by cooling. Its outstanding performance, reliable cooling and comprehensive range of accessories make this centrifuge the ideal choice for routine centrifugation runs. Its maximum capacity of three litres per run makes it a valuable tool in clinics and analytical laboratories, as well as the R&D sections of life science institutions. A large range of accessories is available for high-throughput screening of novel substances in research laboratories. The ROTANTA 460 R is valued in the fields of biotechnology, microbiology and throughout the pharmaceutical industry because of its autoclavable and aerosol-tight accessories. The centrifuge has a rotor with a maximum RCF of 6,446 for the centrifugation of filter plates. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 4880 and 4890 carriers can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020 PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 750 ml in an angle rotor: 6 x 250 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 456 x 770 x 706 mm Weight: approx. 141kg Refrigeration: Infinitely variable from – 20 °C to + 40 °C Frequently used rotors: Swing-out rotor for 4 x 750 ml (90°), max. RCF 5,063 – Cat. No. 5699 Angle rotor for 30 x 1.5 / 2 ml (45°), max. RCF 24,400 - Cat. No. 4489-A Swing-out rotor for max. 12 microtitre plates (90°), max. RCF 6,446 - Cat. No. 5622 ROTANTA 460 R, without rotor, Cat. No. 5660 OPERATOR COMFORT The ROTANTA 460 R makes everyday centrifugation easier because of its ergonomic design. The centrifuge has the following features: Ergonomic operation and display field Simple rotor change Ergonomic C control panel This allows complex centrifugation programs to be entered easily, stored and called up as necessary 98 programmable memories Safeguards against unauthorized operation or changes to stored programs The centrifuge run time can be switched from “at start” (commences from the start) to “at speed” (commences when the set speed has been reached) Special braking ramps for the centrifugation of blood bags Program-linking to connect a number of centrifugation runs (optional) SAFETY ROTANTA benchtop centrifuges have been proven in use for decades in terms of quality and safety. The ROTANTA 460 R has the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection Chamber overheating protection DESIGN The ROTANTA 460 R is a compact benchtop centrifuge of robust construction. It features components such as: Stable metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and display panel Advantages High speeds with fixed-angle rotors: 24,400 RCF at a capacity of 30 x 1.5 / 2.0 ml 18,038 RCF at a capacity of 6 x 94 ml 14,025 RCF at a capacity of 6 x 250 ml High capacities in swing-out rotors 4 x 750 ml at a max. RCF of 4,779 24 microtitre plates / 4 filter plates at a max. RCF of 4,211 or 12 microtitre plates / 2 filter plates at a max. RCF of 6,446 120 blood collection tubes at a max. RCF of 4,637 Comprehensive range of accessories Easy to operate thanks to the C control panel The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F) Stand-by cooling Fields of application The centrifuge is suitable for centrifugation runs in Clinical chemistry Pharmaceutical research (high-throughput screening) Biotechnology Molecular biology
  • Max. capacity in an angle rotor: 24 x 1,5 / 2 ml Max. speed (RPM): 13.300 Max. RCF: 17.008 Dimensions (H x W x D): 228 x 261 x 353 mm Weight: approx. 11 kg Refrigeration: Air cooling Rotor: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 17.008– Cat. No. 1226
  • It can be used for the centrifugation of food samples, cell suspensions, precipitates from chemical reactions, soil samples or blood. The refrigerated centrifuge maintains the samples at the set temperature without fluctuation. In addition to the known blood collection tubes, the centrifuge can also be used for conical tubes with a screw cap, microtitre plates and centrifuge bottles up to 1,000 ml. The inserts for racks used in various blood analysers (e.g., those of Olympus or Hitachi) are a particular advantage. Round-bottom tubes up to 250 ml can also be centrifuged with the ROTIXA 500 RS. The centrifuge has the following capacity per run: 192 blood collection tubes 32 x 50 ml conical tubes with a screw cap 16 microtitre plates of standard format 20 Hitachi racks 4 x 1,000 ml bottles 4 blood bag systems PRODUCT DETAILS Maximum capacity: with swing-out rotor: 4 x 1,000 ml Max. speed (RPM) : 10,000 Max. RCF: 17,441 Dimensions (H x W x D): 973 x 650 x 814 mm Weight: Approx. 219 kg Temperature: Can be set to any desired value in the range -20 °C to +40 °C Commonly used rotors: Swing-out rotor for 4 x 1,000 ml (90°), max. RCF 5,252 – catalogue No. 4294 Swing-out rotor for 6 x 250 ml (90°), max. RCF 3,631 – catalogue No. 4296 Swing-out rotor for up to 16 microtitre plates or various racks (90°), max. RCF 2,652 – catalogue No. 4282 Angle rotor for 14 x 50 ml (36°), max. RCF 17,441 - catalogue No. 4248 OPERATOR COMFORT The refrigerated centrifuge is easy to use and has the following features: Ergonomic operating and display panel Large display, easy to read, showing the current status of all parameters when the centrifuge is running SAFETY The centrifuge has the following features to improve safety: Centrifugation chamber of rust-free stainless steel Lid locking and latching and protection against dropping Emergency lid release Automatic rotor recognition Imbalance switch-off Key-operated switch against unauthorized data change Motor overheating protection Chamber overheating protection DESIGN The ROTIXA 500 RS is a sturdy floor-standing centrifuge with the following features: Stable metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and display panel Viewing port in the lid