  • It can be used for the centrifugation of food samples, cell suspensions, precipitates from chemical reactions, soil samples or blood. The refrigerated centrifuge maintains the samples at the set temperature without fluctuation. In addition to the known blood collection tubes, the centrifuge can also be used for conical tubes with a screw cap, microtitre plates and centrifuge bottles up to 1,000 ml. The inserts for racks used in various blood analysers (e.g., those of Olympus or Hitachi) are a particular advantage. Round-bottom tubes up to 250 ml can also be centrifuged with the ROTIXA 500 RS. The centrifuge has the following capacity per run: 192 blood collection tubes 32 x 50 ml conical tubes with a screw cap 16 microtitre plates of standard format 20 Hitachi racks 4 x 1,000 ml bottles 4 blood bag systems PRODUCT DETAILS Maximum capacity: with swing-out rotor: 4 x 1,000 ml Max. speed (RPM) : 10,000 Max. RCF: 17,441 Dimensions (H x W x D): 973 x 650 x 814 mm Weight: Approx. 219 kg Temperature: Can be set to any desired value in the range -20 °C to +40 °C Commonly used rotors: Swing-out rotor for 4 x 1,000 ml (90°), max. RCF 5,252 – catalogue No. 4294 Swing-out rotor for 6 x 250 ml (90°), max. RCF 3,631 – catalogue No. 4296 Swing-out rotor for up to 16 microtitre plates or various racks (90°), max. RCF 2,652 – catalogue No. 4282 Angle rotor for 14 x 50 ml (36°), max. RCF 17,441 - catalogue No. 4248 OPERATOR COMFORT The refrigerated centrifuge is easy to use and has the following features: Ergonomic operating and display panel Large display, easy to read, showing the current status of all parameters when the centrifuge is running SAFETY The centrifuge has the following features to improve safety: Centrifugation chamber of rust-free stainless steel Lid locking and latching and protection against dropping Emergency lid release Automatic rotor recognition Imbalance switch-off Key-operated switch against unauthorized data change Motor overheating protection Chamber overheating protection DESIGN The ROTIXA 500 RS is a sturdy floor-standing centrifuge with the following features: Stable metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and display panel Viewing port in the lid
  • Max. capacity in an angle rotor: 24 x 1,5 / 2 ml Max. speed (RPM): 13.300 Max. RCF: 17.008 Dimensions (H x W x D): 228 x 261 x 353 mm Weight: approx. 11 kg Refrigeration: Air cooling Rotor: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 17.008– Cat. No. 1226
  • An RCF of 6,446 can be achieved in a swing-out rotor and a value of 24,400 in an angle rotor. The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F). The centrifuge additionally has stand-by cooling. Its outstanding performance, reliable cooling and comprehensive range of accessories make this centrifuge the ideal choice for routine centrifugation runs. Its maximum capacity of three litres per run makes it a valuable tool in clinics and analytical laboratories, as well as the R&D sections of life science institutions. A large range of accessories is available for high-throughput screening of novel substances in research laboratories. The ROTANTA 460 R is valued in the fields of biotechnology, microbiology and throughout the pharmaceutical industry because of its autoclavable and aerosol-tight accessories. The centrifuge has a rotor with a maximum RCF of 6,446 for the centrifugation of filter plates. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 4880 and 4890 carriers can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020 PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 750 ml in an angle rotor: 6 x 250 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 456 x 770 x 706 mm Weight: approx. 141kg Refrigeration: Infinitely variable from – 20 °C to + 40 °C Frequently used rotors: Swing-out rotor for 4 x 750 ml (90°), max. RCF 5,063 – Cat. No. 5699 Angle rotor for 30 x 1.5 / 2 ml (45°), max. RCF 24,400 - Cat. No. 4489-A Swing-out rotor for max. 12 microtitre plates (90°), max. RCF 6,446 - Cat. No. 5622 ROTANTA 460 R, without rotor, Cat. No. 5660 OPERATOR COMFORT The ROTANTA 460 R makes everyday centrifugation easier because of its ergonomic design. The centrifuge has the following features: Ergonomic operation and display field Simple rotor change Ergonomic C control panel This allows complex centrifugation programs to be entered easily, stored and called up as necessary 98 programmable memories Safeguards against unauthorized operation or changes to stored programs The centrifuge run time can be switched from “at start” (commences from the start) to “at speed” (commences when the set speed has been reached) Special braking ramps for the centrifugation of blood bags Program-linking to connect a number of centrifugation runs (optional) SAFETY ROTANTA benchtop centrifuges have been proven in use for decades in terms of quality and safety. The ROTANTA 460 R has the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection Chamber overheating protection DESIGN The ROTANTA 460 R is a compact benchtop centrifuge of robust construction. It features components such as: Stable metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and display panel Advantages High speeds with fixed-angle rotors: 24,400 RCF at a capacity of 30 x 1.5 / 2.0 ml 18,038 RCF at a capacity of 6 x 94 ml 14,025 RCF at a capacity of 6 x 250 ml High capacities in swing-out rotors 4 x 750 ml at a max. RCF of 4,779 24 microtitre plates / 4 filter plates at a max. RCF of 4,211 or 12 microtitre plates / 2 filter plates at a max. RCF of 6,446 120 blood collection tubes at a max. RCF of 4,637 Comprehensive range of accessories Easy to operate thanks to the C control panel The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F) Stand-by cooling Fields of application The centrifuge is suitable for centrifugation runs in Clinical chemistry Pharmaceutical research (high-throughput screening) Biotechnology Molecular biology
  • The ROTO SILENTA 630 RS centrifuges blood bags safely and efficiently. This centrifuge can reliably handle large volumes: Its maximum capacity is 6 x 2,000 ml / 12 x 750 ml blood bags.
  • Max. capacity in an angle rotor: 30 x 1.5 / 2 ml Max. speed (RPM): 15,000 Max. RCF: 21,382 Dimensions (H x W x D): 260 x 281 x 553 mm Weight: approx. 28 kg Refrigeration: Infinitely variable from -20 °C to +40 °C Frequently used rotors: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 21,382 – Cat. No. 2424-B Angle rotor for 30 x 1.5 / 2 ml, two-row, max. RCF 20,627 – Cat. No. 2427-A Angle rotor for 30 x 0.5 ml, max. RCF 20,376 – Cat. No. 2430-B
  • Max. capacity: in a drum rotor: 60 x 1,5 / 2 m in an angle rotor: 48 x 1,5 / 2 ml in a swing-out rotor: 24 x 1,5 / 2 ml Max. speed (RPM): 18.000 Max. RCF: 31.514 Dimensions (H x W x D): 313 x 330 x 420 mm Weight: approx. 21 kg Refrigeration: Air cooling Frequently used rotors: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 31,514 – Cat. No. 1195-A Angle rotor for 48 x 1.5 / 2 ml, two-row, max. RCF 21,255 (outer row) 18,845 (inner row) – Cat. No. 1158-L Swing-out rotor for 24 x 1.5 / 2 ml (90°), max. RCF 18,516 – Cat. No. 1154-L
  • The ROTINA 420 R can handle large volumes. Its maximum capacity of 4 x 600 ml, 140 blood collection tubes or 16 microtitre plates makes it exceptionally suitable for use in medical diagnostics (clinical chemistry). It is also a reliable tool for long term use in biotechnology and pharmaceutical research laboratories. The temperature of the centrifuge can be set to any value in the range -20 °C to +40 °C. The temperature can also be set in Fahrenheit. If toxic or infectious material is centrifuged, then the TÜV-tested accessories with bioseals can protect against aerosols. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 4780 carrier can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020 PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 600 ml in an angle rotor: 4 x 250 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 423 x 713x 654 mm Weight: approx. 108 kg Refrigeration: infinitely variable from – 20°C to +40°C Frequently used rotors: Swing-out rotor for 4 x 600 ml (90°), max. RCF 4,740 – Cat. No. 4784-A Angle rotor for 30 x 1.5 / 2 ml, max. RCF 24,400 – Cat. No. 4790-A Angle rotor for 4 x 250 ml, max. RCF 12,007 – Cat. No. 4795 Angle rotor for 6 x 94 ml, max. RCF 16,504 – Cat. No. 4794 OPERATOR COMFORT The ROTINA 420 R makes everyday centrifugation easier thanks to its ergonomic design. The centrifuge has the following features: Motor-driven lid locking Ergonomic operating and information panel Simple rotor change Ergonomic C control panel 98 programmable memories Additional storage capacity is reserved for the pre-cooling program PREC SAFETY The ROTINA 420 R allows complex tasks to be accomplished easily. It provides the highest degree of safety through the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection Chamber overheating protection DESIGN The ROTINA 420 R is a compact benchtop centrifuge that can handle large volumes. It features components such as: Metal casing Centrifugation chamber of rust-free stainless steel View port in the lid Advantages High-speed and adaptable laboratory centrifuge for daily use in research or analytical laboratories This high-performance centrifuge can hold 4 x 600 ml samples, 140 blood collection tubes or 16 microtitre plates The temperature of the centrifuge can be set to any value in the range -20 °C to +40 °C, with pre-cool program and stand-by cooling The TÜV-tested accessories with bioseals contribute to safe working procedures Compact benchtop centrifuge Ergonomic C control panel allows complex centrifugation programs to be entered, stored and called up as required 98 programmable memories 9 braking and run-up ramps, run-down without braking and braking switch-off speed can be selected as required Fields of application The ROTINA 420 R is a reliable tool for use in laboratories in Medical diagnostics (clinical chemistry) Biotechnology research Pharmaceutical research
  • Max. capacity: in a drum rotor: 60 x 1.5 / 2 ml in an angle rotor: 48 x 1.5 / 2 ml / 6 x 50 ml in a swing-out rotor: 24 x 1.5 / 2 ml Max. speed (RPM): 18,000 Max. RCF: 31,514 Dimensions (H x W x D): 313 x 330 x 650 mm Weight: approx. 42 kg Refrigeration: infinitely variable from – 20°C to +40°C Frequently used rotors: Angle rotor for 24 x 1.5 / 2 ml, max. RCF 31,514 – Cat. No. 1195-A Angle rotor for 48 x 1.5 / 2 ml, two-row, max. RCF 21,255 (outer row) 18,845 (inner row) – Cat. No. 1158-L Swing-out rotor for 24 x 1.5 / 2 ml (90°), max. RCF 18,516 – Cat. No. 1154-L Angle rotor for 6 x 50 ml, max. RCF 4,025 – Cat. No. 1016. The refrigerated MIKRO 220 R also accepts blood collection tubes up to a volume of 10 ml, conical tubes up to 50 ml or standard tubes up to 50 ml.
  • Its maximum capacity of three litres per run makes it a valuable tool in clinics and analytical laboratories, as well as the R&D sections of life science institutions. A large range of accessories is available for high-throughput screening of potential active substances in research laboratories The ROTANTA 460 is valued in the fields of biotechnology and molecular biology and throughout the pharmaceutical industry because of its autoclavable and aerosol-tight accessories. Infectious material can be safely centrifuged. The centrifuge has a rotor with a maximum RCF of 6,446 for the centrifugation of filter plates. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 4880 and 4890 carriers can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020 PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 750 ml in an angle rotor: 6 x 250 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 456 x 554 x 706 mm Weight: approx. 101kg Refrigeration: Air cooling Frequently used rotors: Swing-out rotor for 4 x 750 ml (90°), max. RCF 5,063 – Cat. No. 5699 Angle rotor for 30 x 1.5 / 2 ml (45°), max. RCF 24,400 - Cat. No. 4489-A Angle rotor for 6 x 250 ml (25°), max. RCF 11,228 - Cat. No. 5645 Swing-out rotor for max. 12 microtitre plates (90°), max. RCF 5,838 - Cat. No. 5622 ROTANTA 460, without rotor, Cat. No. 5650 OPERATOR COMFORT The ROTANTA 460 makes everyday centrifugation runs easier because of its ergonomic design. The centrifuge has the following features: Ergonomic operation and display field Simple rotor change Comfortable C control panel This allows complex centrifugation programs to be entered easily, stored and called up as necessary 98 programmable memories Safeguards against unauthorized operation or changes to stored programs The centrifuge run time can be switched from "at start" (commences from the start) to "at speed" (commences when the set speed has been reached) Program-linking to connect a number of centrifugation runs (optional) SAFETY ROTANTA benchtop centrifuges have been proven in use for decades in terms of quality and safety. The ROTANTA 460 has the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection DESIGN The ROTANTA 460 is a compact benchtop centrifuge of robust construction. It features components such as: Stable metal casing Centrifugation chamber of rust-free stainless steel Advantages The centrifuge is designed for a high throughput and efficient sample separation High speeds with fixed-angle rotors: 24,400 RCF at a capacity of 30 x 1.5 / 2.0 ml 18,038 RCF at a capacity of 6 x 94 ml 14,025 RCF at a capacity of 6 x 250 ml High capacities in swing-out rotors 4 x 750 ml at a max. RCF of 4,779 24 microtitre plates / 4 filter plates at a max. RCF of 4,211 or 12 microtitre plates / 2 filter plates at a max. RCF of 6,446 120 blood collection tubes at a max. RCF of 4,637 Comprehensive range of accessories Autoclavable and aerosol-tight accessories Motor-driven lid locking Comfortable operation of the centrifuge thanks to the C control panel Fields of application The centrifuge is suitable for centrifugation runs in Clinical chemistry Pharmaceutical research (high-throughput screening) Biotechnology Molecular biology
  • It has a capacity of 4 x 290 ml and can achieve an RCF of 4,863 without difficulty. If higher speeds are required, then angle rotors are available for 50 ml tubes that have a maximum RCF of 16,504. The ROTINA 380 R can be set to any temperature in the range -20 °C to +40 °C and the temperature can also be set in Fahrenheit. If toxic or infectious material is centrifuged, then the TÜV-tested accessories with bioseals can protect against aerosols. PRODUCT DETAILS Max. capacity: in a swing-out rotor: 4 x 290 ml in an angle rotor: 6 x 94 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 418 x 457 x 750 mm Weight: approx. 81 kg Refrigeration: Infinitely variable from -20 °C to +40 °C Frequently used rotors: Swing-out rotor for 4 x 290 ml (90°), max. RCF 4,863 – Cat. No 1754 Angle rotor for 30 x 1.5 / 2 ml, max. RCF 24,400 – Cat. No. 1789-A Angle rotor for 6 x 94 ml, max. RCF 16,504 – Cat. No. 1792 Cyto rotor for 8 slide preparations, max. RCF 2,415 – Cat. No. 1748 OPERATOR COMFORT The ROTINA 380 R makes everyday centrifugation easier because of its ergonomic design. The centrifuge has the following features: Motor-driven lid locking Ergonomic operating and information panel Simple rotor change 98 programmable memories Additional storage space is allocated to the pre-cooling program PREC SAFETY The ROTINA 380 R contributes to safe working procedures in the laboratory. It has the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection Chamber overheating protection DESIGN The ROTINA 380 R is a compact benchtop centrifuge of robust construction. It features components such as: Metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and display panel Advantages Highly reliable laboratory centrifuge for daily use in research or analytical laboratories. It has a capacity of 4 x 290 ml at a maximum RCF of 4,863 High-performance cooling in the range -20 °C to +40 °C, with a rapid cool program. Protection against aerosols through the TÜV-tested accessories with bioseals Compact benchtop centrifuge Ergonomic C control panel allows complex centrifugation programs to be entered, stored and called up as required 90 programmable memories 9 braking and run-up ramps, run-down without braking and braking switch-off speed can be selected as required Fields of application The ROTINA 380 R is a reliable tool for use in research and analytical laboratories Medical diagnostics (clinical chemistry) Biotechnology research laboratories Pharmaceutical research laboratories
  • Max. capacity in a swing-out rotor: 4 x 290 ml in an angle rotor: 6 x 94 ml Max. speed (RPM): 15,000 Max. RCF: 24,400 Dimensions (H x W x D): 418 x 457 x 600 mm Weight: approx. 51 kg Refrigeration: Air cooling Frequently used rotors: Swing-out rotor for 4 x 290 ml (90°), max. RCF 4,863 – Cat. No 1754 Angle rotor for 30 x 1.5 / 2 ml, max. RCF 24,400 – Cat. No. 1789-A Angle rotor for 6 x 94 ml, max. RCF 13,640 – Cat. No. 1792 Cyto rotor for 8 slide preparations, max. RCF 2,415 – Cat. No. 1748 OPERATOR COMFORT The ROTINA 380 makes everyday centrifugation runs easier thanks to its ergonomic design. The centrifuge has the following features: Motor-driven lid locking Ergonomic operating and information panel Simple rotor change 98 programmable memories Ergonomic C control panel SAFETY The ROTINA 380 contributes to safe working procedures in the laboratory. It has the following features: Lid locking Emergency lid release Lid dropping protection Automatic rotor recognition Imbalance shut-off Motor overheating protection DESIGN The ROTINA 380 is a compact benchtop centrifuge of robust construction. It features components such as: Metal casing Centrifugation chamber of rust-free stainless steel Ergonomic operating and information panel Advantages Highly reliable laboratory centrifuge for daily use in research or analytical laboratories It has a capacity of 4 x 290 ml with a maximum RCF of 4,863 Protection against aerosols through the TÜV-tested accessories with bioseals Compact benchtop centrifuge Ergonomic C control panel allows complex centrifugation programs to be entered, stored and called up as required 98 programmable memories 9 braking and run-up ramps, run-down without braking and braking switch-off speed can be selected as required Fields of application The ROTINA 380 is a reliable tool for use in research and analytical laboratories Medical diagnostics (clinical chemistry) Biotechnology research laboratories Pharmaceutical research laboratories It has a capacity of 4 x 290 ml and can achieve an RCF of 4,863 without difficulty. If higher speeds are required, then angle rotors are available for 50 ml tubes that have a maximum RCF of 13,640. If toxic or infectious material is centrifuged, then the TÜV-tested accessories with bioseals can protect
  • Max. capacity in a swing-out rotor: 4 x 200 ml in an angle rotor: 6 x 85 ml in a hematocrit rotor: 24 standard capillaries Max. speed (RPM): 15,000 Max. RCF: 21,382 Dimensions (H x W x D): 346 x 407 x 698 mm Weight: approx. 53 kg Refrigeration: Infinitely variable from -20 °C to +40 °C Frequently used rotors: Swing-out rotor for 4 x 100 ml (90°), max. RCF 4,193 – Cat. No. 1494 Angle rotor for 30 x 1.5 / 2 ml, max. RCF 21,255 – Cat. No. 1689-A Angle rotor for 6 x 85 ml, max. RCF 9,509 – Cat. No. 1620A Cyto rotor for 6 slide preparations, max. RCF 2,039 – Cat. No. 1626 OPERATOR COMFORT The UNIVERSAL 320 R is particularly easy to use: The operating and display elements of the centrifuge are of ergonomic design The current status of all parameters is displayed while the centrifuge is running 10 programmable memories Switching between the display of speed and the RCF (relative centrifugal force) after entry of the rotor radius in mm Parameters can be quickly and easily entered and changed using the rotary button SAFETY The UNIVERSAL 320 R contributes to safe working procedures in the laboratory. It has the following features: Lid locking Emergency lid release Motor overheating protection Imbalance shut off Automatic rotor recognition Lid dropping protection Chamber overheating protection DESIGN The UNIVERSAL 320 R is a practical benchtop centrifuge with an ergonomic design. It is manufactured from high-quality components and has the following features: Metal casing Metal lid Centrifugation chamber of rust-free stainless steel View port in the lid Carriers and adapters for standard tubes up to 100 ml are available for use at low speeds. In addition, this centrifuge can be used for microtitre plates, tubes with a screw cap, blood collection tubes or cytology accessories. A maximum RCF of 21,382 can be achieved with microlitre tubes. Vessels with higher volumes (up to 85 ml) can also be centrifuged thanks to the high performance of the centrifuge. It is possible to choose between eleven swing-out rotors, seven fixed-angle rotors and one haematocrit rotor. The fixed-angle and swing-out rotors with accessories are suitable for virtually all applications in everyday use in industrial, research and clinical laboratories. Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 1560 carrier can be operated without difficulty with just one hand. The carrier can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. With the clamp in the “open” position the lid can be easily fitted and removed. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020. Advantages High RCF: up to 9,509 for 85-ml tubes and up to 16,582 for 15-ml tubes and 21,382 for reaction tubes Extremely short run-up and run-down times, including rotors running at high speeds High-performance cooling of samples Fast cool function Comprehensive range of accessories: a range of fixed-angle and swing-out rotors Simple rotor change Motor-driven lid locking Ergonomic operating and information panel 10 programmable memories Low noise levels thanks to quiet operation Fields of application The centrifuge is ideal for the centrifugation of samples in the temperature range -20 °C to +40 °C. It is suitable for use in the following fields: Medicine: for example, clinical chemistry Pharmacy Biotechnology
  •   Sua ampla gama de acessórios e excelente desempenho fazem da UNIVERSAL 320 a centrífuga ideal para quase todas as aplicações. Estão disponíveis transportadores e adaptadores para tubos padrão de até 100 ml para uso em baixas velocidades. Além disso, esta centrífuga pode ser usada para placas de microtitulação, tubos com tampa de rosca, tubos de coleta de sangue ou acessórios de citologia.
  • O ROTOFIX 32 A estabeleceu o padrão durante vários anos. Seu alto desempenho a torna a centrífuga de referência em sua classe.    
  • Monitore e controle a umidade e os níveis de oxigênio da incubadora ao trabalhar com estudos de estresse hipóxico, cultura de células-tronco e tumores carcinogênicos com esta incubadora hipóxica de CO2 In-VitroCell™ com controle de umidade. Garanta a sensibilidade e a precisão do controle de gás Sensor cerâmico de O2 de zircônia O sensor de O2 livre de manutenção controla os níveis de oxigênio em culturas celulares, suprimindo-os com nitrogênio. Este processo proporciona maior precisão e controle hipóxico de faixa inferior, com uma faixa de O2 de 0,5 a 21 por cento e uma precisão de O2 de mais ou menos 0,25 por cento. Sensor infravermelho de CO2 Regule os níveis de CO2 da câmara com um sensor infravermelho (IR) de onda dupla de fonte única. Como os comprimentos de onda do sensor são absorvidos apenas pelo CO2, outros componentes, como o vapor d'água, não interferem nas medições. Mantenha a contaminação sob controle Ciclos duplos de esterilização Evite a contaminação com os ciclos duplos de esterilização. A esterilização em alta temperatura utiliza ar seco a 145 graus C, enquanto a descontaminação umidificada opera a 95 graus C e retira a umidade do recipiente de água localizado na parte inferior da câmara. Usando o NuTouch™ ECS, os trabalhadores podem programar o processo de esterilização para ser executado em um horário conveniente. Cantos internos abobadados A câmara interna oferece uma construção sem fendas e cantos internos arredondados que não promovem o crescimento biológico. A superfície de aço inoxidável polido é inerte e fácil de limpar. Tecnologia Sistema de controle eletrônico NuTouch™ (ECS) Controle o ambiente da câmara com precisão e eficiência com a interface touchscreen colorida do Sistema de Controle Eletrônico (ECS) NuTouch™. O ECS fornece controle operacional, outros parâmetros operacionais críticos e indicadores de status, além de armazenar valores, mesmo durante interrupções de energia. Filtragem HEPA de circuito fechado Mantenha as condições de ajuste da câmara com o sistema de filtragem HEPA de circuito fechado. Amostras de ar de dois locais da câmara passam por um filtro HEPA de 99,99% antes de entrar no compartimento do sensor, que mede os níveis de gás e umidade. Com base nesses níveis, o NuTouch™ ECS determina quando injetar gás CO2 filtrado por HEPA, ar, nitrogênio e vapor no ambiente de crescimento. Este sistema de circuito fechado filtra continuamente o ar da câmara, reduzindo o fluxo de ar para uma única troca de ar a cada 20 minutos para minimizar a dessecação. Também mantém a pressão de ar positiva, evitando que ar de laboratório potencialmente contaminado entre na câmara, mesmo quando a porta está aberta. Controle de umidade relativa Fornece o nível adequado de umidade com controle de umidade relativa. Um sensor de umidade relativa monitora o nível de umidade e, quando é necessário aumentá-lo, o vapor é injetado de um reservatório de água de aço inoxidável localizado sob o gabinete. Desempenho Uniformidade de temperatura Os elementos de aquecimento em todos os lados da câmara fornecem calor direto para uma uniformidade superior da temperatura da incubadora. Sensores duplos monitoram a temperatura da câmara e ajustam-na conforme necessário. Vibração mínima Promova o crescimento celular reduzindo a vibração. Esta incubadora possui menos peças móveis e uma bomba de ar para injetar ar e gás, ajudando-a a funcionar sem problemas.
  • Nosso analisador portátil de CO2 foi projetado especificamente para monitorar CO2 para verificação de incubadoras em mercados de pesquisa e farmacêuticos. O principal benefício de usar o G100 é a capacidade de leituras simultâneas de CO2, O2, umidade relativa e temperatura.
  • A In-VitroCell™ ES NU-5741 5,65 Ft3 (160 L) Hipóxica Calor Direto CO2 Incubadora foi projetada para fornecer aos laboratórios um ambiente in vitro controlado para estudos relacionados à idade ou pesquisas com células-tronco. O NU-5741 fornece condições ideais de crescimento, controlando com precisão a umidade, temperatura, oxigênio e CO2, monitorando e controlando o ambiente de crescimento. Tecnologia de destaque Sistema de controle eletrônico NuTouch O sistema de controle eletrônico NuTouch da incubadora de CO2 com calor direto In-VitroCell™ ES NU-5741 de 5,65 pés3 (160 L) facilita o controle. O sistema de controle NuTouch é um sistema colorido com tela sensível ao toque, para que você possa controlar facilmente os parâmetros do sistema com apenas um toque de um dedo. Condições hipóxicas A câmara da incubadora pode oferecer condições hipóxicas, usando um sensor para controle de O2 e injetando gás N2 para atingir um ponto de ajuste na faixa de 0,5% a 21%, com precisão de ±0,25%. Controle Preciso de Contaminação Ciclos duplos de esterilização A incubadora NU-5741 foi projetada com ciclos duplos de esterilização para proteger os produtos na câmara e o pessoal do laboratório. Os ciclos duplos são a 145°C seco e 95°C umidificado. Projetado para proteção A incubadora foi projetada com canto arredondado e interior sem fendas, o que facilita a limpeza e limita possíveis esconderijos de contaminação. Filtragem HEPA de circuito fechado O sistema de filtragem HEPA de circuito fechado na incubadora modelo NU-5741 também foi projetado para minimizar o risco de contaminação. O sistema é semelhante ao de uma sala limpa ISO classe 5, mantida a uma pressão positiva, com gás e ar passando continuamente por filtros HEPA com 99,99% de eficiência. Sem vibração A incubadora não vibra, pois há menos peças móveis. A vibração reduzida ajuda a proteger as linhas celulares. Recursos exclusivos de desempenho Controle de umidade O controle de umidade no NU-5741 é gerenciado por meio de um reservatório de três litros que injeta vapor d'água para atingir um ponto definido de até 95%. Este sistema é usado na incubadora no lugar de um reservatório de água do usuário. O sistema de controle de umidade tem precisão de +5% / -3%. Tempos de recuperação mais rápidos A incubadora NU-5741 apresenta tempos de recuperação mais rápidos após a abertura da porta, o que ajuda a manter a temperatura, os níveis de gás CO2 e O2. Níveis precisos de CO2 Há um sensor infravermelho de onda dupla na incubadora que ajuda a manter concentrações adequadas de CO2 na câmara de crescimento, com precisão de ±0,1 por cento. O sensor é insensível a outros componentes, como vapor de água. Temperatura Uniforme A temperatura uniforme na incubadora (±0,3°C) é monitorada utilizando sondas duplas de temperatura. Recursos padrão Sistema de controle eletrônico NuTouch Sistema de filtragem HEPA de circuito fechado Ciclos duplos de esterilização (145°C seco, 95°C umidificado) Câmara de crescimento de aço inoxidável polido tipo 304 de calibre 16 Prateleiras de aço inoxidável polido tipo 16 calibre 304 (Qtd 4) Suportes de aço inoxidável polido tipo 304 de calibre 16 (Qtd 4) Guias de prateleira de aço inoxidável polido tipo 16 calibre 304 (Qtd 8) Sensor infravermelho (IR) Sistema de controle e recuperação de umidade (UR) Reservatório de água em aço inoxidável apenas para instalação e calibração Sistema de monitoramento e controle de O2 Porta de amostragem de CO2 Sistema de isolamento R5 Aquecedor de porta independente Porta externa reversível com dobradiça direita Porta de vidro interna reversível com dobradiça direita Junta da porta interna removível/autoclavável Niveladores de pernas para serviços pesados Porta USB Porta de comunicação RJ-11 para conexão de alarme remoto Conector RJ-45 - Comunicação bidirecional RS-485 Saída: Controlar níveis do sistema e alarmes/eventos Entrada: Comandos de um computador para visualizar e atualizar parâmetros operacionais Conector RJ-45 - Saída analógica de 4-20 mA para monitorar todos os níveis do sistema de controle ativo Porta de acesso utilitário Cabo de alimentação elétrica Empilhável em campo com modelos apropriados de incubadora NuAire In-VitroCell ES 5700 160L Incubadora hipóxica de calor direto de CO2 com ciclos duplos de esterilização, umidade e controles de O2.
  • In-VitroCell ES NU-8631 5,65 cu. pés (160L) Incubadora hipóxica de CO2 com camisa de água e controle de O2 Incubadora de CO2 com sistema de monitoramento e controle de oxigênio para suprimir os níveis de oxigênio na câmara de crescimento, injetando nitrogênio para pesquisa de hipóxia. A temperatura é controlada usando sondas de sensor de temperatura dupla que aquecem a água ao redor da câmara de crescimento para um ambiente mais estável.
  •   Automatic blood-components extractor. This device can process any kind of centrifuged blood-bags with whole blood, buffycoat, platelet rich plasma and others.
  • Specifications Constant and uniform mixing of blood Automatic tare for the empty bag Automatic clamp at the end of the donation Adjustable low/high flow alarms Adjustable donation time-out 3D mixing system Blue/white graphics display with backlight Wireless and cable data transmission Memory card Barcode reader Removable and rechargeable battery Customizable barcode protocol on Windows environment Weighing range from 10 to 990 ml EU or US date format Up to 1000 donations can be stored in the internal memory 5 supported user-interface languages Can work without power for up to 50 donations Class 1 medical device Monitor de coleta de sangue com leitor de código de barras. Interface de software e hardware para transferência de dados para um computador.
  • Composed of radio frequency generator, battery charger, and sealing hSelador de tubos móvel para tubos de PVC de bolsas de sangue.
  •   Monitor eletrônico de coleta de sangue com zero automático, alarme de fluxo, temporizador máximo de doação, bateria.
  •   Seladoras de tubos de bancada com pinça simples ou quádrupla.
  •   Seladoras de tubos de bancada com pinça simples ou quádrupla.